Rosyjski język Angielski język Polski język
Download Catalogi
Mapka

Tabele

Load tables were developed for panels with 0,5 mm thick linings and the difference in temperatures ΔT=40°C. In case of a different thickness of panel or dark colours of lining it is necessary to carry out separate calculations. Minimum width of supports - 40 mm.

LOAD TABLES - GORLICKA S 1000

Table showing maximum available load for: Wall insulated panel Gorlicka S 1000 0,5 mm thick in light colours, installed as SINGLE-SPAN element in a direction to and from the support.

Panel thickness

Load on account of:

Maximum load [daN/m2] with a span range [m]

2,1

2,4

2,7

3,0

3,3

3,6

3,9

4,2

4,5

4,8

5,1

5,4

5,7

6,0

40

Load

207

158

125

101

84

                 

Stiffness

96

72

54

41

32

                 

60

Load

 

241

191

155

128

107

91

79

68

60

       

Stiffness

 

145

114

91

73

59

48

40

33

27

       

80

Load

   

257

208

172

144

122

106

92

81

72

64

58

52

Stiffness

   

182

149

122

101

84

71

60

50

43

37

31

27

100

Load

     

248

204

172

147

126

110

96

86

77

68

62

Stiffness

     

190

159

135

115

98

84

73

63

54

47

41

Table showing maximum available load for: Wall insulated panel Gorlicka S 1000 0,5 mm thick in light colours, installed as MULTI-SPAN element in a direction to and from the support.

Panel thickness

Load on account of:

Maximum load [daN/m2] with a span range [m]

2,1

2,4

2,7

3,0

3,3

3,6

3,9

4,2

4,5

4,8

5,1

5,4

5,7

6,0

40

Load

255

180

131

99

78

63

52

43

37

         

Stiffness

132

108

89

74

63

53

46

39

34

         

60

Load

 

326

231

172

133

106

86

71

60

52

45

     

Stiffness

 

185

156

133

114

98

86

75

66

58

51

     

80

Load

   

355

260

198

156

126

103

87

74

63

55

49

43

Stiffness

   

227

195

169

147

129

114

101

90

81

72

65

59

100

Load

     

367

275

212

168

137

113

95

81

70

61

54

Stiffness

     

227

199

175

156

139

125

112

101

92

83

76

LOAD TABLES - GORLICKA U 1000

Table showing maximum available load for: Wall insulated panel Gorlicka U 1000 0,5 mm thick in light colours, installed as SINGLE-SPAN element in a direction to and from the support.

Panel thickness

Load on account of:

Maximum load [daN/m2] with a span range [m]

2,1

2,4

2,7

3,0

3,3

3,6

3,9

4,2

4,5

4,8

5,1

5,4

5,7

6,0

60

Load

 

241

191

155

128

107

91

79

68

60

       

Stiffness

 

145

114

91

73

59

48

40

33

27

       

80

Load

   

257

208

172

144

122

106

92

81

72

64

58

52

Stiffness

   

182

149

122

101

84

71

60

50

43

37

31

27

100

Load

     

248

204

172

147

126

110

96

86

77

68

62

Stiffness

     

190

159

135

115

98

84

73

63

54

47

41

Table showing maximum available load for: Wall insulated panel Gorlicka U 1000 0,5 mm thick in light colours, installed as SINGLE-SPAN element in a direction from the support.

Panel thickness

Load on account of:

Maximum load [daN/m2] with a span range [m]

2,1

2,4

2,7

3,0

3,3

3,6

3,9

4,2

4,5

4,8

5,1

5,4

5,7

6,0

60

Load

 

145

115

93

77

64

55

47

41

36

       

Stiffness

 

109

86

68

55

44

36

30

25

20

       

80

Load

   

154

125

103

86

73

64

55

49

43

38

35

31

Stiffness

   

137

112

92

76

63

53

45

38

32

28

23

20

100

Load

     

149

122

103

88

76

66

58

52

46

41

37

Stiffness

     

143

119

101

86

74

63

55

47

41

35

31

Table showing maximum available load for: Wall insulated panel Gorlicka U 1000 0,5 mm thick in light colours, installed as MULTI-SPAN element in a direction to the support.

Panel thickness

Load on account of:

Maximum load [daN/m2] with a span range [m]

2,1

2,4

2,7

3,0

3,3

3,6

3,9

4,2

4,5

4,8

5,1

5,4

5,7

6,0

60

Load

 

326

231

172

133

106

86

71

60

52

45

     

Stiffness

 

185

156

133

114

98

86

75

66

58

51

     

80

Load

   

355

260

198

156

126

103

87

74

63

55

49

43

Stiffness

   

227

195

169

147

129

114

101

90

81

72

65

59

100

Load

     

367

275

212

168

137

113

95

81

70

61

54

Stiffness

     

227

199

175

156

139

125

112

101

92

83

76

able showing maximum available load for: Wall insulated panel Gorlicka U 1000 0,5 mm thick in light colours, installed as MULTI-SPAN element in a direction from the support.

Panel thickness

Load on account of:

Maximum load [daN/m2] with a span range [m]

2,1

2,4

2,7

3,0

3,3

3,6

3,9

4,2

4,5

4,8

5,1

5,4

5,7

6,0

60

Load


196

139

103

80

64

52

43

36

31

27




Stiffness


139

117

100

86

74

65

56

50

44

38




80

Load



213

156

119

94

76

62

52

44

38

33

29

26

Stiffness



170

146

127

110

97

86

76

68

61

54

49

44

100

Load




220

165

127

101

82

68

57

49

42

37

32

Stiffness




170

149

131

117

104

94

84

76

69

62

57

LOAD TABLES - GORLICKA D 1000

Table showing maximum available load for: Roof insulated panel Gorlicka D 1000 with linings that are 0,5 mm thick, in light colours, installed as MULTI-SPAN element in a direction to the support.

Panel thickness

Load on account of:

Maximum load [daN/m2] with a span range [m]

2,1

2,4

2,7

3,0

3,3

3,6

3,9

4,2

4,5

4,8

5,1

5,4

5,7

6,0

40

Load

207

179

158

124

98

79

65

55

47

         

Stiffness

223

182

150

125

106

90

77

66

57

         

60

Load

 

252

221

197

161

130

106

88

75

65

56

50

   

Stiffness

 

260

218

185

159

137

119

104

91

80

71

63

   

80

Load

   

286

255

230

186

152

126

106

91

79

69

61

 

Stiffness

   

289

247

214

186

163

143

127

113

101

90

81

 

100

Load

     

318

285

250

202

166

139

118

101

88

77

68

Stiffness

     

260

227

200

177

158

142

128

115

104

95

86

Table showing maximum available load for: Roof insulated panel D 10000,5 mm thick, in light colours, installed as MULTI-SPAN element in a direction from the support.

Panel thickness

Load on account of:

Maksymalne obciążenie [daN/m2] przy rozpiętości przęsła [m]

2,1

2,4

2,7

3,0

3,3

3,6

3,9

4,2

4,5

4,8

5,1

5,4

5,7

6,0

40

Load

145

125

111

87

69

55

46

39

33

         

Stiffness

190

155

128

106

90

77

65

56

48

         

60

Load

 

176

155

138

113

91

74

62

53

46

39

35

   

Stiffness

 

221

185

157

135

116

101

88

77

68

60

54

   

80

Load

   

200

179

161

130

106

88

74

64

55

48

43

 

Stiffness

   

246

210

182

158

139

122

108

96

86

77

69

 

100

Load

     

223

200

175

141

116

97

83

71

62

54

48

Stiffness

     

221

193

170

150

134

121

109

98

88

81

73

.